Archive | October 11, 2011

04 Fiber Distribution Cable MM 62.5/125 Indoor/Outdoor Riser

Distribution Cable Indoor/Outdoor

This FiberSavvy.com Distribution Riser Rated Fiber Optic Cable is ideal for Indoor/outdoor tight-bound tight-buffered design allows cables to be installed in inter-building backbone and inter-building campus locations without costly transitions between cable types. This is ideal configuration for a single termination point requiring multiple fibers.

FiberSavvy.com Distribution Riser Rated Fiber Optic Cable are high performance components and construction and It’s UL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor.

Our indoor/outdoor tight buffered fiber optic cables meet the functional requirements of the following standards

  • GR-409-CORE
  • ICEA-S-104-696
  • ICEA-S-83-596
  • TIA-568
  • TIA-598

Features

  • Applications:
    • Indoor/outdoor tight-bound tight-buffered design allows cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types
    • Ideal configuration for a single termination point requiring multiple fibers
  • Cost Savings:
    • 900 micron buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber
    • No need to splice outdoor cable to indoor cable at building entrance
    • High crush resistance may eliminate the need for innerduct
  • Features:
    • High performance components and construction
    • Cable materials are indoor/outdoor – UL-listed OFNR and UV, water and fungus resistant
    • UL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor
    • Wide operating temperature range of -40°C to +85°C
    • Helically stranded core for greater flexibility and mechanical protection of the optical fibers
    • High strength-to-weight ratio
    • 2-144 fiber configuration is smaller and lighter than comparable sub-grouped cables made by others: ideal for installation in areas with limited space or tight bends
    • Can be armored for additional protection in direct burial and aerial installations
    • Interlocking armor can be applied to cables as an alternative to conduit installation

General Characteristics

Operating Temperature -40°C to +85°C
Storage Temperature -55°C to +85°C
Installation Temperature (cable temp.) -10°C to +60°C
Flame Retardancy UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)
Crush Resistance 1,800 N/cm
Impact Resistance 1,500 impacts
Flex Resistance 2,000 cycles

These specifications are subject to change without prior notification.